X3-45 Commuter

Prevost, a division of Volvo Group Canada Inc. Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2012-09-04
Run Number: 1
Personnel: T.S., S.R. & M.Z.
Test Direction: CCW
Ambient Temperature (°F): 72
Humidity (%): 94
SLW (lbs): 47110
Wind Speed (mpg) & Direction: 0/Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:41 8:41 39.6 0.583
ART #1 0 4:00 4:00 41.1 0.521
CBD #2 0 8:40 8:40 41.1 0.6
Art #2 0 4:06 4:06 43.1 0.516
CBD #3 0 8:42 8:42 42.5 0.6
Commuter 0 5:57 5:57 44.3 0.514
Total Fuel: 3.3340000000000005 SCF
20 minute idle: .290 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19618 BTU/LB
Comments: None noted.

Date: 2012-09-04
Run Number: 2
Personnel: T.S., S.R. & M.Z.
Test Direction: CW
Ambient Temperature (°F): 72
Humidity (%): 94
SLW (lbs): 47110
Wind Speed (mpg) & Direction: 0/Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:57 8:57 44.1 0.579
ART #1 0 4:05 4:05 44.3 0.515
CBD #2 0 8:46 8:46 43.2 0.597
Art #2 0 4:09 4:09 40.8 0.502
CBD #3 0 8:46 8:46 43.3 0.597
Commuter 0 5:59 5:59 44.9 0.509
Total Fuel: 3.2989999999999995 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19618 BTU/LB
Comments: None noted.

Date: 2012-09-04
Run Number: 3
Personnel: T.S., S.R. & M.Z.
Test Direction: CCW
Ambient Temperature (°F): 75
Humidity (%): 83
SLW (lbs): 47110
Wind Speed (mpg) & Direction: 5/S
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:55 8:55 40.2 0.565
ART #1 0 4:03 4:03 43.4 0.486
CBD #2 0 8:43 8:43 42.7 0.606
Art #2 0 4:09 4:09 45.4 0.492
CBD #3 0 8:46 8:46 44.3 0.595
Commuter 0 5:59 5:59 46.4 0.514
Total Fuel: 3.258 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19618 BTU/LB
Comments: None noted.

Date: 2012-09-04
Run Number: 4
Personnel: T.S., S.R. & M.Z.
Test Direction: CW
Ambient Temperature (°F): 77
Humidity (%): 74
SLW (lbs): 47110
Wind Speed (mpg) & Direction: 5/SSW
Barometric Pressure (in.Hg): 29
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:53 8:53 45.6 0.57
ART #1 0 4:07 4:07 44.6 0.498
CBD #2 0 8:41 8:41 44.6 0.593
Art #2 0 4:01 4:01 46.7 0.505
CBD #3 0 8:47 8:47 45.3 0.594
Commuter 0 6:00 6:00 46.6 0.539
Total Fuel: 3.299 SCF
20 minute idle: .300 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19618 BTU/LB
Comments: None noted.