D4000 N

MOTOR COACH INDUSTRIES Pdf Download PDF Report

Static Towing Test Data Form

Date: 2003-02-21
Personnel: E.D., D.L., K.D., & B.T.
Temperature: 34

 

Inspect right front tow eye and adjoining structure.
Comments: Welds inspected and confirmed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left front tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect right rear tow eye and adjoining structure.
Comments: Welds inspected and confirmed.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
All four front pulls were completed to the full test load of 41,172 lbs. No damage or deformation was observed during testing. No rear test was performed due to design.