Propane Vision

Blue Bird Body Company Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2013-07-03
Run Number: 1
Personnel: T.S., S.R. & M.Z.
Test Direction: CCW
Ambient Temperature (°F): 76
Humidity (%): 82
SLW (lbs): 24820
Wind Speed (mpg) & Direction: 8/SW
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:55 8:55 94.1 0.733
ART #1 0 4:07 4:07 95.0 0.591
CBD #2 0 8:42 8:42 95.1 0.674
Art #2 0 4:06 4:06 96.9 0.639
CBD #3 0 8:45 8:45 96.7 0.686
Commuter 0 6:00 6:00 97.4 0.733
Total Fuel: 4.055999999999999 SCF
20 minute idle: 0.320 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19904 BTU/LB
Comments: None noted.

Date: 2013-07-03
Run Number: 2
Personnel: T.S., S.R. & M.Z.
Test Direction: CW
Ambient Temperature (°F): 76
Humidity (%): 81
SLW (lbs): 24820
Wind Speed (mpg) & Direction: 6/SW
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:55 8:55 94.3 0.58
ART #1 0 4:10 4:10 95.7 0.558
CBD #2 0 8:48 8:48 96.6 0.698
Art #2 0 4:07 4:07 99.2 0.58
CBD #3 0 8:47 8:47 99.4 0.686
Commuter 0 6:02 6:02 101.6 0.674
Total Fuel: 3.776 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19904 BTU/LB
Comments: None noted.

Date: 2013-07-03
Run Number: 3
Personnel: T.S., S.R. & M.Z.
Test Direction: CCW
Ambient Temperature (°F): 79
Humidity (%): 76
SLW (lbs): 24820
Wind Speed (mpg) & Direction: 3/SW
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:00 9:00 94.9 0.674
ART #1 0 4:09 4:09 95.4 0.603
CBD #2 0 8:55 8:55 97.0 0.662
Art #2 0 4:13 4:13 99.1 0.674
CBD #3 0 8:57 8:57 100.0 0.627
Commuter 0 6:02 6:02 101.8 0.721
Total Fuel: 3.9610000000000003 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19914 BTU/LB
Comments: None noted.

Date: 2013-07-03
Run Number: 4
Personnel: T.S., S.R. & M.Z.
Test Direction: CW
Ambient Temperature (°F): 81
Humidity (%): 74
SLW (lbs): 24820
Wind Speed (mpg) & Direction: 5/SW
Barometric Pressure (in.Hg): 28
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:49 8:49 99.4 0.721
ART #1 0 4:11 4:11 101.4 0.603
CBD #2 0 8:49 8:49 101.7 0.615
Art #2 0 4:10 4:10 103.8 0.627
CBD #3 0 8:45 8:45 104.0 0.686
Commuter 0 5:53 5:53 106.0 0.674
Total Fuel: 3.9259999999999997 SCF
20 minute idle: 0.320 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19914 BTU/LB
Comments: None noted.