XDE60

NEW FLYER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2014-09-25
Run Number: 1
Personnel: T.S., E.L. & C.S.
Test Direction: CCW
Ambient Temperature (°F): 60
Humidity (%): 88
SLW (lbs): 49
Wind Speed (mpg) & Direction: 2/NNE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:10 9:10 18.0 0.481
ART #1 0 4:19 4:19 18.7 0.512
CBD #2 0 9:05 9:05 19.3 0.428
Art #2 0 4:14 4:14 19.3 0.517
CBD #3 0 9:08 9:08 19.1 0.475
Commuter 0 6:07 6:07 19.9 0.6
Total Fuel: 3.0130000000000003 SCF
20 minute idle: .183 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19568 BTU/LB
Comments: Bus has automatic shutdown at idle.

Date: 2014-09-25
Run Number: 3
Personnel: T.S., E.L. & C.S.
Test Direction: CCW
Ambient Temperature (°F): 63
Humidity (%): 72
SLW (lbs): 49
Wind Speed (mpg) & Direction: 4/E
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:16 9:16 22.8 0.452
ART #1 0 4:14 4:14 23.7 0.514
CBD #2 0 9:04 9:04 25.1 0.445
Art #2 0 4:19 4:19 24.5 0.524
CBD #3 0 9:08 9:08 25.6 0.469
Commuter 0 6:03 6:03 25.3 0.604
Total Fuel: 3.008 SCF
20 minute idle: N/A SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19,568 BTU/LB
Comments: None noted.

Date: 2014-09-25
Run Number: 4
Personnel: T.S., E.L. & C.S.
Test Direction: CW
Ambient Temperature (°F): 69
Humidity (%): 73
SLW (lbs): 49
Wind Speed (mpg) & Direction: 2/E
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:16 9:16 25.0 0.453
ART #1 0 4:16 4:16 25.7 0.517
CBD #2 0 8:55 8:55 27.1 0.408
Art #2 0 4:17 4:17 26.4 0.521
CBD #3 0 8:54 8:54 27.8 0.443
Commuter 0 6:09 6:09 27.3 0.572
Total Fuel: 2.914 SCF
20 minute idle: .184 SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19,568 BTU/LB
Comments: None noted.

Date: 2014-09-25
Run Number: 2
Personnel: T.S., E.L. & C.S.
Test Direction: CW
Ambient Temperature (°F): 62
Humidity (%): 77
SLW (lbs): 49
Wind Speed (mpg) & Direction: 2/ENE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:15 9:15 19.6 0.473
ART #1 0 4:20 4:20 20.6 0.521
CBD #2 0 9:11 9:11 21.3 0.42
Art #2 0 4:20 4:20 21.3 0.483
CBD #3 0 9:12 9:12 22.1 0.438
Commuter 0 6:05 6:05 21.8 0.593
Total Fuel: 2.928 SCF
20 minute idle: N/A SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 19,568 BTU/LB
Comments: None noted.