Static Towing Test Data Form
Date:
|
2014-12-17
|
Personnel:
|
S.R., T.G., E.L. & J.S.
|
Temperature:
|
34
|
Inspect right front tow eye and adjoining structure. |
Comments:
20 degree upward pull. Damage occured to the adjoining structure of the tow hooks. Further testing was terminated.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Test terminated.
|
Inspect left front tow eye and adjoining structure. |
Comments:
20 degree upward pull. Damage occured to the adjoining structure of the tow hooks. Further testing was terminated.
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
Test terminated.
|
Inspect right rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
Inspect left rear tow eye and adjoining structure. |
Comments:
N/A
|
Check the torque of all bolts attaching tow eye and surrounding structure. |
Comments:
N/A
|
General comments of any other structure deformation or failure: |
<p>During the 20 degree upward pull the bumper structure the tow hooks are attached to deformed and started to crack. Further testing was terminated.</p> |
|
|
General
Check-In
Maintainability
Repair & Maintenance
Replacement & Repair
Reliability
Safety
Performance
Structural
Fuel Economy
Noise
Glossary
Back to Bus List
|