BE40

PROTERRA, INC. Pdf Download PDF Report

Static Towing Test Data Form

Date: 2015-04-09
Personnel: S.R., E.L., P.D., J.P. & J.S.
Temperature: 45

 

Inspect right front tow eye and adjoining structure.
Comments: No damage or deformation.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds inspected.
Inspect left front tow eye and adjoining structure.
Comments: No damage or deformation.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: Welds inspected.
Inspect right rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
<p>All four front pulls were completed to the ful target test load of 16,422 lbs. (1.2 x 27,370 &divide; 2 = 16,422) with no damage or deformation observed. The manufacturer does not recommend towing from the rear; therefore a rear test was not performed.</p>