C 40 LF

NEW FLYER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2003-01-13
Run Number: 1
Personnel: S.C. & B.S.
Test Direction: CCW
Ambient Temperature (°F): 30
Humidity (%): 66
SLW (lbs): 36080
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 9:00 9:00 65.0 97.8
ART #1 0 4:10 4:10 65.0 76.0
CBD #2 0 8:47 8:47 65.0 91.0
Art #2 0 4:11 4:11 65.0 75.3
CBD #3 0 8:42 8:42 66.0 87.9
Commuter 0 6:05 6:05 67.0 91.1
Total Fuel: 519.1 SCF
20 minute idle: 69.0 SCF
No Load Flow Rate at Idle = 2.32 SCFM No Load Flow Rate at Full Throttle = 11.27 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-01-13
Run Number: 2
Personnel: S.C. & B.S.
Test Direction: CW
Ambient Temperature (°F): 30
Humidity (%): 66
SLW (lbs): 36080
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:50 8:50 65.0 88.1
ART #1 0 4:20 4:20 68.0 71.7
CBD #2 0 8:59 8:59 66.0 87.5
Art #2 0 4:22 4:22 68.0 70.9
CBD #3 0 8:53 8:53 67.0 88.4
Commuter 0 6:03 6:03 68.0 96.2
Total Fuel: 502.8 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-01-13
Run Number: 3
Personnel: S.C. & B.S.
Test Direction: CCW
Ambient Temperature (°F): 31
Humidity (%): 60
SLW (lbs): 36080
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:49 8:49 68.0 90.5
ART #1 0 4:15 4:15 68.0 75.5
CBD #2 0 9:02 9:02 69.0 88.7
Art #2 0 4:21 4:21 68.0 74.7
CBD #3 0 8:59 8:59 70.0 91.4
Commuter 0 6:06 6:06 69.0 97.3
Total Fuel: 518.0999999999999 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-01-13
Run Number: 4
Personnel: S.C. & B.S.
Test Direction: CW
Ambient Temperature (°F): 31
Humidity (%): 60
SLW (lbs): 36080
Wind Speed (mpg) & Direction: 10/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:51 8:51 69.0 88.1
ART #1 0 4:15 4:15 70.0 70.3
CBD #2 0 8:40 8:40 69.0 86.4
Art #2 0 4:11 4:11 69.0 70.3
CBD #3 0 8:57 8:57 69.0 88.5
Commuter 0 6:22 6:22 69.0 99.0
Total Fuel: 502.59999999999997 SCF
20 minute idle: 56.1 SCF
No Load Flow Rate at Idle = 2.25 SCFM No Load Flow Rate at Full Throttle = 10.15 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None