ELDORADO NATIONAL Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2003-08-18
Run Number: 1
Personnel: B.S. and S.C.
Test Direction: CCW
Ambient Temperature (°F): 70
Humidity (%): 68
SLW (lbs): 3005072
Wind Speed (mpg) & Direction: 3/NE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:43 8:43 92.8 71.6
ART #1 0 4:08 4:08 89.3 56.0
CBD #2 0 8:36 8:36 92.3 70.4
Art #2 0 4:05 4:05 91.6 57.0
CBD #3 0 8:40 8:40 90.5 71.5
Commuter 0 6:25 6:25 86.8 72.8
Total Fuel: 399.3 SCF
20 minute idle: 30.2 SCF
No Load Flow Rate at Idle = 1.27 SCFM No Load Flow Rate at Full Throttle = 9.01 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-08-18
Run Number: 2
Personnel: B.S. and S.C.
Test Direction: CCW
Ambient Temperature (°F): 73
Humidity (%): 56
SLW (lbs): 30050
Wind Speed (mpg) & Direction: 7/NE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:50 8:50 91.2 71.0
ART #1 0 4:08 4:08 91.3 52.1
CBD #2 0 8:42 8:42 102.3 68.9
Art #2 0 4:10 4:10 98.6 53.4
CBD #3 0 8:49 8:49 96.7 73.9
Commuter 0 6:09 6:09 98.8 78.8
Total Fuel: 398.1 SCF
20 minute idle: 0.0 SCF
No Load Flow Rate at Idle = 0.0 SCFM No Load Flow Rate at Full Throttle = 0.0 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-08-18
Run Number: 3
Personnel: B.S. and S.C.
Test Direction: CCW
Ambient Temperature (°F): 75
Humidity (%): 50
SLW (lbs): 30050
Wind Speed (mpg) & Direction: 5/NE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:41 8:41 101.5 70.8
ART #1 0 4:07 4:07 99.5 54.3
CBD #2 0 8:52 8:52 100.5 77.0
Art #2 0 4:10 4:10 99.6 56.4
CBD #3 0 8:44 8:44 99.0 75.9
Commuter 0 6:04 6:04 99.5 71.4
Total Fuel: 405.79999999999995 SCF
20 minute idle: 0.0 SCF
No Load Flow Rate at Idle = 0.0 SCFM No Load Flow Rate at Full Throttle = 0.0 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2003-08-18
Run Number: 4
Personnel: B.S. and S.C.
Test Direction: CW
Ambient Temperature (°F): 77
Humidity (%): 50
SLW (lbs): 30050
Wind Speed (mpg) & Direction: 5/NE
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:40 8:40 99.3 73.9
ART #1 0 4:13 4:13 95.5 54.1
CBD #2 0 8:44 8:44 97.4 73.5
Art #2 0 4:12 4:12 96.6 57.2
CBD #3 0 8:46 8:46 96.8 70.4
Commuter 0 6:10 6:10 100.6 74.2
Total Fuel: 403.3 SCF
20 minute idle: 30.3 SCF
No Load Flow Rate at Idle = 1.54 SCFM No Load Flow Rate at Full Throttle = 9.07 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None