AERO ELITE

ELDORADO NATIONAL Pdf Download PDF Report

Static Towing Test Data Form

Date: 2004-05-19
Personnel: T.S., R.C., M.H., & S.C.
Temperature: 75

 

Inspect right front tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left front tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect right rear tow eye and adjoining structure.
Comments: Torques verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
All four front pulls were completed to the full target test weight of 16,152 lbs with no damage or deformation observed. The rear test was not performed due to the lack of rear tow eyes or tow hooks.