C40LF

NEW FLYER Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2004-06-01
Run Number: 1
Personnel: R.C., T.S., & S.C.
Test Direction: CCW
Ambient Temperature (°F): 66
Humidity (%): 68
SLW (lbs): 35300
Wind Speed (mpg) & Direction: 9/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:48 8:48 112.4 83.3
ART #1 0 4:06 4:06 110.5 54.1
CBD #2 0 8:40 8:40 108.4 80.3
Art #2 0 4:05 4:05 108.4 51.9
CBD #3 0 8:41 8:41 108.5 73.9
Commuter 0 6:06 6:06 110.1 71.4
Total Fuel: 414.9 SCF
20 minute idle: 60.3 SCF
No Load Flow Rate at Idle = 2.58 SCFM No Load Flow Rate at Full Throttle = 11.37 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2004-06-01
Run Number: 2
Personnel: R.C., T.S., & R.C.
Test Direction: CW
Ambient Temperature (°F): 69
Humidity (%): 68
SLW (lbs): 35300
Wind Speed (mpg) & Direction: 8/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:32 8:32 110.2 75.5
ART #1 0 4:03 4:03 110.4 51.4
CBD #2 0 8:29 8:29 109.7 73.4
Art #2 0 4:03 4:03 108.5 51.6
CBD #3 0 8:24 8:24 109.1 71.4
Commuter 0 6:02 6:02 108.8 73.0
Total Fuel: 396.3 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2004-06-01
Run Number: 3
Personnel: R.C., T.S., & S.C.
Test Direction: CCW
Ambient Temperature (°F): 70
Humidity (%): 56
SLW (lbs): 35300
Wind Speed (mpg) & Direction: 9/W
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:35 8:35 109.5 79.3
ART #1 0 4:00 4:00 109.3 52.7
CBD #2 0 8:33 8:33 109.1 76.6
Art #2 0 4:02 4:02 109.4 52.7
CBD #3 0 8:29 8:29 109.2 74.8
Commuter 0 6:05 6:05 109.5 72.8
Total Fuel: 408.90000000000003 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2004-06-01
Run Number: 4
Personnel: R.C., T.S., & S.C.
Test Direction: CCW
Ambient Temperature (°F): 72
Humidity (%): 49
SLW (lbs): 35300
Wind Speed (mpg) & Direction: 10/SW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:28 8:28 112.8 72.8
ART #1 0 4:02 4:02 111.1 51.7
CBD #2 0 8:25 8:25 109.4 72.5
Art #2 0 4:01 4:01 109.6 51.5
CBD #3 0 8:29 8:29 110.1 72.6
Commuter 0 6:04 6:04 110.0 73.1
Total Fuel: 394.20000000000005 SCF
20 minute idle: 56.5 SCF
No Load Flow Rate at Idle = 2.45 SCFM No Load Flow Rate at Full Throttle = 10.64 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None