Structural Shakedown Data Form
Loading Sequence:
1
Date:
2005-05-24
|
Temperature:
78
|
Personnel:
D.L., E.D., E.L., and M.H.
|
Test Load (lbs):
43875
|
Reference Point No. |
A (in) Original Height |
B (in) Loaded Height |
B-A (in) Loaded Deflection |
C (in) Unloaded Height |
C-A (in) Permanent Deflection |
1 |
0.000 |
0.054 |
0.054 |
0.024 |
0.024 |
2 |
0.000 |
0.059 |
0.059 |
0.009 |
0.009 |
3 |
0.000 |
0.068 |
0.068 |
0.006 |
0.006 |
4 |
0.000 |
0.039 |
0.039 |
0.000 |
0.000 |
5 |
0.000 |
0.080 |
0.080 |
0.001 |
0.001 |
6 |
0.000 |
0.009 |
0.009 |
0.006 |
0.006 |
7 |
0.000 |
0.025 |
0.025 |
0.017 |
0.017 |
8 |
0.000 |
0.087 |
0.087 |
0.018 |
0.018 |
9 |
0.000 |
0.036 |
0.036 |
0.012 |
0.012 |
10 |
0.000 |
0.083 |
0.083 |
0.009 |
0.009 |
11 |
0.000 |
0.068 |
0.068 |
0.011 |
0.011 |
12 |
0.000 |
0.052 |
0.052 |
0.022 |
0.022 |
Loading Sequence:
1
Date:
2005-05-24
|
Temperature:
78
|
Personnel:
D.L., E.D., E.L., and M.H.
|
Test Load (lbs):
43875
|
Reference Point No. |
A (in) Original Height |
B (in) Loaded Height |
B-A (in) Loaded Deflection |
C (in) Unloaded Height |
C-A (in) Permanent Deflection |
1 |
0.024 |
0.059 |
0.035 |
0.029 |
0.005 |
2 |
0.009 |
0.062 |
0.053 |
0.008 |
-0.001 |
3 |
0.006 |
0.069 |
0.063 |
0.008 |
0.002 |
4 |
0.000 |
0.044 |
0.044 |
0.000 |
0.000 |
5 |
0.001 |
0.083 |
0.082 |
0.006 |
0.005 |
6 |
0.006 |
0.009 |
0.003 |
0.003 |
-0.003 |
7 |
0.017 |
0.031 |
0.014 |
0.015 |
-0.002 |
8 |
0.018 |
0.092 |
0.074 |
0.023 |
0.005 |
9 |
0.012 |
0.047 |
0.035 |
0.012 |
0.000 |
10 |
0.009 |
0.088 |
0.079 |
0.011 |
0.002 |
11 |
0.011 |
0.077 |
0.066 |
0.012 |
0.001 |
12 |
0.022 |
0.056 |
0.034 |
0.024 |
0.002 |
|
|
General
Check-In
Maintainability
Repair & Maintenance
Replacement & Repair
Reliability
Safety
Performance
Structural
Fuel Economy
Noise
Glossary
Back to Bus List
|