LOWFLOOR

GILLIG CORPORATION Pdf Download PDF Report

Structural Shakedown Data Form

Loading Sequence: 1

Date: 2004-06-10 Temperature: 78
Personnel: D.L., M.H., T.S. & E.L. Test Load (lbs): 28125
Reference Point No. A (in) Original Height B (in) Loaded Height B-A (in) Loaded Deflection C (in) Unloaded Height C-A (in) Permanent Deflection
1 0.000 0.036 0.036 0.033 0.033
2 0.000 0.128 0.128 0.029 0.029
3 0.000 0.186 0.186 0.045 0.045
4 0.000 0.181 0.181 0.038 0.038
5 0.000 0.158 0.158 0.035 0.035
6 0.000 0.009 0.009 0.004 0.004
7 0.000 0.010 0.010 0.001 0.001
8 0.000 0.183 0.183 0.035 0.035
9 0.000 0.212 0.212 0.039 0.039
10 0.000 0.214 0.214 0.036 0.036
11 0.000 0.135 0.135 0.023 0.023
12 0.000 0.011 0.011 0.036 0.036

Loading Sequence: 1

Date: 2004-06-10 Temperature: 78
Personnel: D.L., M.H., T.S. & E.L. Test Load (lbs): 28125
Reference Point No. A (in) Original Height B (in) Loaded Height B-A (in) Loaded Deflection C (in) Unloaded Height C-A (in) Permanent Deflection
1 0.033 0.045 0.012 0.034 0.001
2 0.029 0.140 0.111 0.032 0.003
3 0.045 0.204 0.159 0.050 0.005
4 0.038 0.200 0.162 0.043 0.005
5 0.035 0.175 0.140 0.040 0.005
6 0.004 0.006 0.002 0.005 0.001
7 0.001 0.000 -0.001 0.002 0.001
8 0.035 0.185 0.150 0.041 0.006
9 0.039 0.219 0.180 0.004 -0.035
10 0.036 0.219 0.183 0.041 0.005
11 0.023 0.139 0.116 0.026 0.003
12 0.036 0.012 -0.024 0.040 0.004

Loading Sequence: 1

Date: 2004-06-10 Temperature: 78
Personnel: D.L., M.H., T.S. & E.L. Test Load (lbs): 28125
Reference Point No. A (in) Original Height B (in) Loaded Height B-A (in) Loaded Deflection C (in) Unloaded Height C-A (in) Permanent Deflection
1 0.000 0.000 0.000 0.000 0.000
2 0.000 0.000 0.000 0.000 0.000
3 0.000 0.000 0.000 0.000 0.000
4 0.000 0.000 0.000 0.000 0.000
5 0.000 0.000 0.000 0.000 0.000
6 0.000 0.000 0.000 0.000 0.000
7 0.000 0.000 0.000 0.000 0.000
8 0.000 0.000 0.000 0.000 0.000
9 0.000 0.000 0.000 0.000 0.000
10 0.000 0.000 0.000 0.000 0.000
11 0.000 0.000 0.000 0.000 0.000
12