LOWFLOOR

GILLIG CORPORATION Pdf Download PDF Report

Jacking Test Data Form

Date: 2004-06-08
Personnel: S.C.
Temperature: 70
Right front
11.4" I
8.2" D
8.6" I
5.3" D
Left front
11.3" I
11.3" D
8.6" I
5.1" D
Right rear outside
27.0" I
24.0" D
10.3" I
9.5" D
Right rear both
27.0" I
21.8" D
10.3" I
8.1" D
Left rear outside
26.8" I
23.9" D
10.3" I
9.6" D
Left rear both
26.8" I
21.7" D
10.3" I
8.0" D
Right middle or tag outside
0.0" I

Right middle or tag both


Left middle or tag outside


Left middle or tag both