LOWFLOOR

GILLIG CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 2004-11-23
Personnel: R.C., T.S., M.H. & S.C.
Temperature: 49

 

Inspect right front tow eye and adjoining structure.
Comments: Welds verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left front tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
Inspect right rear tow eye and adjoining structure.
Comments: Welds verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left rear tow eye and adjoining structure.
Comments:
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments:
General comments of any other structure deformation or failure:
All four front pulls were completed to the full target test load of 32,688 lbs (1.2 x 27,240 lbs) with no damage or deformation observed. The manufacturer does not recommend rear towing, therefore, a rear test was not performed.