240 TRANSTECH
ELDORADO NATIONAL
|
Date | : | 2005-06-02 | |||
Personnel | : | R.C., D..L. & S.C. | |||
Temperature (°F) | : | 74 | Humidity (%) | : | 44 |
Wind Speed (mph) | : | 8 | Wind Direction | : | SE |
Barometric Pressure (in.Hg) | : | 30.21 | |||
Verify that microphone height is 4 feet, wind speed is less than 12 mpg and ambient temperature is between 30 F and 90 F: true checked by S.C. | |||||
Initial Sound Level Meter Calibration: true checked by S,C, | |||||
Exterior Ambient Noise Level dB(A): 46.2 |
Accelerating from Constant Speed
Curb (Right) Side |
Accelerating from Constant Speed
Street (Left) Side |
||
---|---|---|---|
Run # | Measured Noise Level dB(A) | Run # | Measured Noise Level dB(A) |
1 | 69.7 | 1 | 71.7 |
2 | 70.4 | 2 | 71.6 |
3 | 70.5 | 3 | 72.6 |
4 | 70.5 | 4 | 71.6 |
5 | 70.4 | 5 | 71.5 |
Average of two highest actual noise levels = 70.5 dB(A) | Average of two highest actual noise levels = 72.2 dB(A) |
Final Sound Level Meter Calibration Check: true checked by S.C. |
Comments: |
General
Check-In
Back to Bus List
- Summary
- Weight
- Clearances
- Body Details
- Engine
- Transmission
- Suspension
- Wheels & Tires
- Brakes
- HVAC
- Steering
- Capacities
- Misc.
- Components
- Spare Parts
- Integrity Summary
- Shakedown
- Distortion Summary
- Distortion Test
- Static Towing Summary
- Static Towing Test
- Dynamic Towing Summary
- Dynamic Towing Test
- Jacking Summary
- Jacking Test
- Hoisting Summary
- Hoisting Test
- Durability Summary
- Durability Mileage
- Unscheduled Maintenance
- Interior Summary
- Stationary Test
- Acceleration Test
- Vibration Test
- Exterior Summary
- Constant Acceleration
- Standstill Acceleration
- Stationary
Back to Bus List